Visual performance of optical films utilizing Spatio-Temporal Optical Phase technology

Cathleen Fedtke, Daniel Tilia, Klaus Ehrmann, Jennie Diec, Karen Lahav-Yacouel, Darrin Falk, Ravi C. Bakaraju

Research output: Contribution to journalArticlepeer-review

Abstract

SIGNIFICANCE Spatio-Temporal Optical Phase technology utilizes film pairs containing optical elements applied to standard single-vision spectacle lenses. This technology provides a dynamic optical cue that may have efficacy in reducing the rate of myopia progression, but the visual performance of this technology is unknown. PURPOSE This study aimed to assess the visual performance of film pairs containing optical elements (tests) and a film pair with no optical elements (control). METHODS In this randomized, single-masked, bilateral wear study, 42 participants aged 18 to 40 years wore four test designs (E, F-1, G, and F-2) and the control. Subjective data (subjective ratings [1 to 10 scale]: clarity of vision [far-away, intermediate, near] and vision [at night, while walking, overall satisfaction], and willingness to purchase [yes/no response]) were collected after 3 days. Visual acuity (VA)-based measures (monocular high/low-contrast VA [6 m], contrast sensitivity [6 m], and binocular high-contrast VA [6 m and 40 cm]) were collected at dispensing. Visual acuity-based measures were also collected while wearing spectacles with no film. Analyses were performed using linear mixed models and the χ2 test. Significance was set at 5%. RESULTS The control performed better than any test for all subjective ratings (mean differences, 1.6 to 3.1 units: p<0.001), willingness to purchase (p<0.001), and designs F-1 and F-2 for binocular high-contrast VA at 40 cm (p=0.001 and p=0.01, respectively). Clarity of vision was significantly worse with F-2 compared with F-1 and G (p<0.001 and p=0.02, respectively). There were no differences between tests for any other subjective rating (p>0.1), willingness to purchase (p=0.11), or any VA-based measure (p>0.08). There were no differences between control and spectacles with no film for any VA-based measure (p>0.08). CONCLUSIONS All four test film pairs reduced visual performance compared with control to a degree comparable with other myopia management devices. There was no difference in visual performance between three of the four test film pairs.

Original languageEnglish
Pages (from-to)195-203
Number of pages9
JournalOptometry and Vision Science
Volume101
Issue number4
DOIs
StatePublished - 1 Apr 2024
Externally publishedYes

Bibliographical note

Publisher Copyright:
© American Academy of Optometry.

Fingerprint

Dive into the research topics of 'Visual performance of optical films utilizing Spatio-Temporal Optical Phase technology'. Together they form a unique fingerprint.

Cite this