Skip to main navigation Skip to search Skip to main content

Self-discharge of graphite electrodes at elevated temperatures studied by CV and electrochemical impedance spectroscopy

  • Bar-Ilan University

Research output: Contribution to journalArticlepeer-review

33 Scopus citations

Abstract

We propose a new method for the kinetic treatment of self-discharge of intercalation electrodes based on a combination of cyclic voltammetry (CV) and chronopotentiometry under net zero current conditions. This was applied to composite graphite electrodes in 1 M LiPF6 /ethylene carbonate + dimethyl carbonate (1:1) + 5 % dimethyl polycarbonate at four different temperatures from 25 to 80°C, and was quantitatively proved for small degrees of self-discharge. The degree of self-discharge and the self-discharge current, Isd, were shown to substantially increase with the increase in temperature. Self-discharge experiments, which continued for 50 h, were complemented by detailed impedance characterizations of the gradually discharged electrodes, which show an increase in the diameter of the high-frequency semicircles (HFS) with open-circuit time at different temperatures. A comparison between Arrhenius plots for the HFS, the chemical diffusion coefficient, and the self-discharge current may create a basis for a new method of "electrochemical temperature spectroscopy" for identification of the nature of the rate-determining step of self-discharge for different temperature ranges. Our results are discussed in light of studies by others of self-discharge phenomena and mechanisms (Li-graphite electrodes).

Original languageEnglish
Pages (from-to)A781-A790
JournalJournal of the Electrochemical Society
Volume151
Issue number5
DOIs
StatePublished - 2004

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 7 - Affordable and Clean Energy
    SDG 7 Affordable and Clean Energy

Fingerprint

Dive into the research topics of 'Self-discharge of graphite electrodes at elevated temperatures studied by CV and electrochemical impedance spectroscopy'. Together they form a unique fingerprint.

Cite this