Right ventricular outflow tract velocity time integral-to-pulmonary artery systolic pressure ratio: a non-invasive metric of pulmonary arterial compliance differs across the spectrum of pulmonary hypertension

Priyanka T. Bhattacharya, Gregory S. Troutman, Frances Mao, Arieh L. Fox, Monique S. Tanna, Payman Zamani, E. Wilson Grandin, Jonathan N. Menachem, Edo Y. Birati, Julio A. Chirinos, Sula Mazimba, Kerri Akaya Smith, Steven M. Kawut, Paul R. Forfia, Anjali Vaidya, Jeremy A. Mazurek

Research output: Contribution to journalArticlepeer-review

14 Scopus citations

Abstract

Pulmonary arterial compliance (PAC), invasively assessed by the ratio of stroke volume to pulmonary arterial (PA) pulse pressure, is a sensitive marker of right ventricular (RV)-PA coupling that differs across the spectrum of pulmonary hypertension (PH) and is predictive of outcomes. We assessed whether the echocardiographically derived ratio of RV outflow tract velocity time integral to PA systolic pressure (RVOT-VTI/PASP) (a) correlates with invasive PAC, (b) discriminates heart failure with preserved ejection-associated PH (HFpEF-PH) from pulmonary arterial hypertension (PAH), and (c) is associated with functional capacity. We performed a retrospective cohort study of patients with PAH (n = 70) and HFpEF-PH (n = 86), which was further dichotomized by diastolic pressure gradient (DPG) into isolated post-capillary PH (DPG < 7 mmHg; Ipc-PH, n = 54), and combined post- and pre-capillary PH (DPG ≥ 7 mm Hg; Cpc-PH, n = 32). Of the 156 patients, 146 had measurable RVOT-VTI or PASP and were included in further analysis. RVOT-VTI/PASP correlated with invasive PAC overall (ρ = 0.61, P < 0.001) and for the PAH (ρ = 0.38, P = 0.002) and HFpEF-PH (ρ = 0.63, P < 0.001) groups individually. RVOT-VTI/PASP differed significantly across the PH spectrum (PAH: 0.13 [0.010–0.25] vs. Cpc-PH: 0.20 [0.12–0.25] vs. Ipc-PH: 0.35 [0.22–0.44]; P < 0.001), distinguished HFpEF-PH from PAH (AUC = 0.72, 95% CI = 0.63–0.81) and Cpc-PH from Ipc-PH (AUC = 0.78, 95% CI = 0.68–0.88), and remained independently predictive of 6-min walk distance after multivariate analysis (standardized β-coefficient = 27.7, 95% CI = 9.2–46.3; P = 0.004). Echocardiographic RVOT-VTI/PASP is a novel non-invasive metric of PAC that differs across the spectrum of PH. It distinguishes the degree of pre-capillary disease within HFpEF-PH and is predictive of functional capacity.

Original languageEnglish
JournalPulmonary Circulation
Volume9
Issue number2
DOIs
StatePublished - 1 Apr 2019
Externally publishedYes

Bibliographical note

Publisher Copyright:
© The Author(s) 2019.

Funding

This work was supported in part by NIH grant K24-HL103844 (SMK).

FundersFunder number
National Institutes of Health
NIH Clinical CenterK24-HL103844

    Keywords

    • Cpc-PH
    • non-invasive
    • pulmonary arterial compliance
    • pulmonary hypertension

    Fingerprint

    Dive into the research topics of 'Right ventricular outflow tract velocity time integral-to-pulmonary artery systolic pressure ratio: a non-invasive metric of pulmonary arterial compliance differs across the spectrum of pulmonary hypertension'. Together they form a unique fingerprint.

    Cite this