TY - JOUR
T1 - Real-time quantification of protein expression and translocation at individual cell resolution using imaging-dish-based live cell array
AU - Ravid-Hermesh, Orit
AU - Zurgil, Naomi
AU - Shafran, Yana
AU - Sobolev, Maria
AU - Galmidi, Moti
AU - Badihi, Yoav
AU - Israel, Liron Limor
AU - Lellouche, Jean Paul
AU - Lellouche, Emmanuel
AU - Michaeli, Shulamit
AU - Deutsch, Mordechai
N1 - Publisher Copyright:
© 2014 Springer-Verlag Berlin Heidelberg.
PY - 2014/11
Y1 - 2014/11
N2 - Cell populations represent intrinsically heterogeneous systems with a high level of spatiotemporal complexity. Monitoring and understanding cell-to-cell diversity is essential for the research and application of intra- and interpopulation variations. Optical analysis of live cells is challenging since both adherent and nonadherent cells change their spatial location. However, most currently available single-cell techniques do not facilitate treatment and monitoring of the same live cells over time throughout multistep experiments. An imaging-dish-based live cell array (ID-LCA) has been developed and produced for cell handling, culturing, and imaging of numerous live cells. The dish is composed of an array of pico scale cavities - pico wells (PWs) embossed on its glass bottom. Cells are seeded, cultured, treated, and spatiotemporally measured on the ID-LCA, while each cell or small group of cells are locally constrained in the PWs. Finally, predefined cells can be retrieved for further evaluation. Various types of ID-LCAs were used in this proof-of-principle work, to demonstrate on-ID-LCA transfection of fluorescently tagged chimeric proteins, as well as the detection and kinetic analysis of their induced translocation. High variability was evident within cell populations with regard to protein expression levels as well as the extent and dynamics of protein redistribution. The association of these parameters with cell morphology and functional parameters was examined. Both the new methodology and the device facilitate research of the translocation process at individual cell resolution within large populations and thus, can potentially be used in high-throughput fashion. [Figure not available: see fulltext.]
AB - Cell populations represent intrinsically heterogeneous systems with a high level of spatiotemporal complexity. Monitoring and understanding cell-to-cell diversity is essential for the research and application of intra- and interpopulation variations. Optical analysis of live cells is challenging since both adherent and nonadherent cells change their spatial location. However, most currently available single-cell techniques do not facilitate treatment and monitoring of the same live cells over time throughout multistep experiments. An imaging-dish-based live cell array (ID-LCA) has been developed and produced for cell handling, culturing, and imaging of numerous live cells. The dish is composed of an array of pico scale cavities - pico wells (PWs) embossed on its glass bottom. Cells are seeded, cultured, treated, and spatiotemporally measured on the ID-LCA, while each cell or small group of cells are locally constrained in the PWs. Finally, predefined cells can be retrieved for further evaluation. Various types of ID-LCAs were used in this proof-of-principle work, to demonstrate on-ID-LCA transfection of fluorescently tagged chimeric proteins, as well as the detection and kinetic analysis of their induced translocation. High variability was evident within cell populations with regard to protein expression levels as well as the extent and dynamics of protein redistribution. The association of these parameters with cell morphology and functional parameters was examined. Both the new methodology and the device facilitate research of the translocation process at individual cell resolution within large populations and thus, can potentially be used in high-throughput fashion. [Figure not available: see fulltext.]
KW - Biochip
KW - Fluorescence
KW - Imaging
KW - Kinetics
KW - Microfabrication
KW - Single-cell analysis
UR - http://www.scopus.com/inward/record.url?scp=84937511086&partnerID=8YFLogxK
U2 - 10.1007/s00216-014-8157-1
DO - 10.1007/s00216-014-8157-1
M3 - ???researchoutput.researchoutputtypes.contributiontojournal.article???
C2 - 25258284
AN - SCOPUS:84937511086
SN - 1618-2642
SP - 7085
EP - 7101
JO - Analytical and Bioanalytical Chemistry
JF - Analytical and Bioanalytical Chemistry
ER -