Abstract
A real-time density feedback control system with a 100 GHz heterodyne interferometer has been designed, developed, and commissioned in ADITYA-U tokamak. It consists of three subsystems i.e. density measurement, feedback control, and gas fuelling. A proportional feedback controller is configured in voltage amplitude mode to operate the piezo valve for gas injection. Experiments are performed during plasma discharges to achieve a predefined density evolution as well as constant density. Stickiness of the piezo valve restricts the temporal response of the valve. It is required to minimize during the plasma discharge for a fast density response which is achieved by a short preceding voltage pulse known as a stick pulse. This paper describes the implementation of a real-time density feedback control system which is successfully validated using another existing 140 GHz interferometer system in ADITYA-U. Moreover, the developed system consumes low power, is cost-effective and re-programmable, can be easily upgraded, and provides interlock with plasma parameters.
Original language | English |
---|---|
Article number | P06004 |
Journal | Journal of Instrumentation |
Volume | 17 |
Issue number | 6 |
DOIs | |
State | Published - 1 Jun 2022 |
Externally published | Yes |
Bibliographical note
Publisher Copyright:© 2022 IOP Publishing Ltd and Sissa Medialab.
Keywords
- Density feedback
- Flow control
- Gas injection
- Interferometer
- Piezo control
- Real-time density
- Stickiness