Radiotherapy-Induced Cardiac Implantable Electronic Device Dysfunction in Patients With Cancer

Rodrigo Bagur, Mathilde Chamula, Émilie Brouillard, Caroline Lavoie, Luis Nombela-Franco, Anne Sophie Julien, Louis Archambault, Nicolas Varfalvy, Valérie Gaudreault, Sébastien X. Joncas, Zeev Israeli, Yasir Parviz, Mamas A. Mamas, Shahar Lavi

Research output: Contribution to journalArticlepeer-review

36 Scopus citations

Abstract

Radiotherapy can affect the electronic components of a cardiac implantable electronic device (CIED) resulting in malfunction and/or damage. We sought to assess the incidence, predictors, and clinical impact of CIED dysfunction (CIED-D) after radiotherapy for cancer treatment. Clinical characteristics, cancer, different types of CIEDs, and radiation dose were evaluated. The investigation identified 230 patients, mean age 78 ± 8 years and 70% were men. A total of 199 patients had pacemakers (59% dual chamber), 21 (9%) cardioverter-defibrillators, and 10 (4%) resynchronizators or defibrillators. The left pectoral (n = 192, 83%) was the most common CIED location. Sixteen patients (7%) experienced 18 events of CIED-D after radiotherapy. Reset to backup pacing mode was the most common encountered dysfunction, and only 1 (6%) patient of those with CIED-D experienced symptoms of atrioventricular dyssynchrony. Those who had CIED-D tended to have a shorter device age at the time of radiotherapy compared to those who did not (2.5 ± 1.5 vs 3.8 ± 3.4 years, p = 0.09). The total dose prescribed to the tumor was significantly greater among those who had CIED-D (66 ± 30 vs 42 ± 23 Gy, p <0.0001). Multivariate logistic regression analysis identified the total dose prescribed to the tumor as the only independent predictor for CIED-D (odds ratio 1.19 for each increase in 5 Gy, 95% confidence interval 1.08 to 1.31, p = 0.0005). In conclusion, in this large population of patients with CIEDs undergoing radiotherapy for cancer treatment, the occurrence of newly diagnosed CIED-D was 7%, and the reset to backup pacing mode was the most common encountered dysfunction. The total dose prescribed to the tumor was a predictor of CIED-D. Importantly, although the unpredictability of CIEDs under radiotherapy is still an issue, none of our patients experienced significant symptoms, life-threatening arrhythmias, or conduction disorders.

Original languageEnglish
Pages (from-to)284-289
Number of pages6
JournalAmerican Journal of Cardiology
Volume119
Issue number2
DOIs
StatePublished - 15 Jan 2017
Externally publishedYes

Bibliographical note

Publisher Copyright:
© 2016 Elsevier Inc.

Fingerprint

Dive into the research topics of 'Radiotherapy-Induced Cardiac Implantable Electronic Device Dysfunction in Patients With Cancer'. Together they form a unique fingerprint.

Cite this