T1 - Radiotherapy-Induced Cardiac Implantable Electronic Device Dysfunction in Patients With Cancer
AU - Bagur, Rodrigo
AU - Chamula, Mathilde
AU - Brouillard, Émilie
AU - Lavoie, Caroline
AU - Nombela-Franco, Luis
AU - Julien, Anne Sophie
AU - Archambault, Louis
AU - Varfalvy, Nicolas
AU - Gaudreault, Valérie
AU - Joncas, Sébastien X.
AU - Israeli, Zeev
AU - Parviz, Yasir
AU - Mamas, Mamas A.
AU - Lavi, Shahar
N1 - Publisher Copyright:
© 2016 Elsevier Inc.
PY - 2017/1/15
Y1 - 2017/1/15
N2 - Radiotherapy can affect the electronic components of a cardiac implantable electronic device (CIED) resulting in malfunction and/or damage. We sought to assess the incidence, predictors, and clinical impact of CIED dysfunction (CIED-D) after radiotherapy for cancer treatment. Clinical characteristics, cancer, different types of CIEDs, and radiation dose were evaluated. The investigation identified 230 patients, mean age 78 ± 8 years and 70% were men. A total of 199 patients had pacemakers (59% dual chamber), 21 (9%) cardioverter-defibrillators, and 10 (4%) resynchronizators or defibrillators. The left pectoral (n = 192, 83%) was the most common CIED location. Sixteen patients (7%) experienced 18 events of CIED-D after radiotherapy. Reset to backup pacing mode was the most common encountered dysfunction, and only 1 (6%) patient of those with CIED-D experienced symptoms of atrioventricular dyssynchrony. Those who had CIED-D tended to have a shorter device age at the time of radiotherapy compared to those who did not (2.5 ± 1.5 vs 3.8 ± 3.4 years, p = 0.09). The total dose prescribed to the tumor was significantly greater among those who had CIED-D (66 ± 30 vs 42 ± 23 Gy, p <0.0001). Multivariate logistic regression analysis identified the total dose prescribed to the tumor as the only independent predictor for CIED-D (odds ratio 1.19 for each increase in 5 Gy, 95% confidence interval 1.08 to 1.31, p = 0.0005). In conclusion, in this large population of patients with CIEDs undergoing radiotherapy for cancer treatment, the occurrence of newly diagnosed CIED-D was 7%, and the reset to backup pacing mode was the most common encountered dysfunction. The total dose prescribed to the tumor was a predictor of CIED-D. Importantly, although the unpredictability of CIEDs under radiotherapy is still an issue, none of our patients experienced significant symptoms, life-threatening arrhythmias, or conduction disorders.
AB - Radiotherapy can affect the electronic components of a cardiac implantable electronic device (CIED) resulting in malfunction and/or damage. We sought to assess the incidence, predictors, and clinical impact of CIED dysfunction (CIED-D) after radiotherapy for cancer treatment. Clinical characteristics, cancer, different types of CIEDs, and radiation dose were evaluated. The investigation identified 230 patients, mean age 78 ± 8 years and 70% were men. A total of 199 patients had pacemakers (59% dual chamber), 21 (9%) cardioverter-defibrillators, and 10 (4%) resynchronizators or defibrillators. The left pectoral (n = 192, 83%) was the most common CIED location. Sixteen patients (7%) experienced 18 events of CIED-D after radiotherapy. Reset to backup pacing mode was the most common encountered dysfunction, and only 1 (6%) patient of those with CIED-D experienced symptoms of atrioventricular dyssynchrony. Those who had CIED-D tended to have a shorter device age at the time of radiotherapy compared to those who did not (2.5 ± 1.5 vs 3.8 ± 3.4 years, p = 0.09). The total dose prescribed to the tumor was significantly greater among those who had CIED-D (66 ± 30 vs 42 ± 23 Gy, p <0.0001). Multivariate logistic regression analysis identified the total dose prescribed to the tumor as the only independent predictor for CIED-D (odds ratio 1.19 for each increase in 5 Gy, 95% confidence interval 1.08 to 1.31, p = 0.0005). In conclusion, in this large population of patients with CIEDs undergoing radiotherapy for cancer treatment, the occurrence of newly diagnosed CIED-D was 7%, and the reset to backup pacing mode was the most common encountered dysfunction. The total dose prescribed to the tumor was a predictor of CIED-D. Importantly, although the unpredictability of CIEDs under radiotherapy is still an issue, none of our patients experienced significant symptoms, life-threatening arrhythmias, or conduction disorders.
UR - http://www.scopus.com/inward/record.url?scp=85006168504&partnerID=8YFLogxK
U2 - 10.1016/j.amjcard.2016.09.036
DO - 10.1016/j.amjcard.2016.09.036
M3 - ???researchoutput.researchoutputtypes.contributiontojournal.article???
C2 - 27823600
AN - SCOPUS:85006168504
SN - 0002-9149
VL - 119
SP - 284
EP - 289
JO - American Journal of Cardiology
JF - American Journal of Cardiology
IS - 2
ER -