Optimization of tablet processing as a reference material for microplastic detection methods

  • Mara Putzu
  • , Yosri Wiesner
  • , Christiane Weimann
  • , Vasile Dan Hodoroaba
  • , Soledad Muniategui Lorenzo
  • , Verónica Fernández-Gonzáles
  • , Andy M. Booth
  • , Amaia Igartua
  • , Nizar Benismail
  • , Laureen Coïc
  • , Carine Chivas-Joly
  • , Ivana Fenoglio
  • , Andrea Mario Rossi
  • , Andrea Mario Giovannozzi
  • , Korinna Altmann

Research output: Contribution to journalArticlepeer-review

Abstract

Reference materials (RMs) are essential and highly demanded tools for the development and validation of methods for microplastic (MP) quantification in complex matrices, to ensure comparable and harmonized approaches aligned with EU commission criteria for monitoring MPs (e.g., Drinking Water Directive and Urban Wastewater Treatment Directive). This study investigates different approaches for optimizing the production of polypropylene (PP) RMs in the form of water-soluble tablets, which were carefully evaluated for their homogeneity and stability according to ISO Guide 30, ISO 33401, and ISO 33405. PP particles (1–100 μm) were produced by cryomilling and embedded in a lactose/PEG matrix, then pressed into tablets (18 µg theoretical PP mass). The production process was optimized by varying (i) the size distribution of the matrix components and (ii) the mixer instrument. The materials obtained were characterized by thermogravimetric analysis to assess the homogeneity distribution of MPs with respect to PP mass in the individual tablets and their stability over a 4-month period. The most promising approach, with a homogenous mass of 19 μg (standard deviation of 4 μg), relative standard deviation of 19%, was further investigated for homogeneity by comparison with thermo-analytical mass determination methods, such as TED-GC/MS (thermal extraction desorption-gas chromatography/mass spectrometry) and Py-GC/MS (pyrolysis-gas chromatography-mass spectrometry), and for number-based characterization using micro-Raman spectroscopy. Material characterization was also examined using laser diffraction, scanning electron microscopy, and ATR-FTIR. Based on the results, the optimized processing protocol yields a PP RM suitable for quality control and method performance studies supporting standardization.

Original languageEnglish
JournalAnalytical and Bioanalytical Chemistry
Early online date11 Dec 2025
DOIs
StateE-pub ahead of print - 11 Dec 2025
Externally publishedYes

Bibliographical note

Publisher Copyright:
© The Author(s) 2025.

Keywords

  • Analytical methods
  • Identification
  • Plastic polymer
  • Polypropylene
  • Quantification
  • Validation

Fingerprint

Dive into the research topics of 'Optimization of tablet processing as a reference material for microplastic detection methods'. Together they form a unique fingerprint.

Cite this