Abstract
The ScienceWorkshop data acquisition system with DATASTUDIO software is capable of performing lock-in detection of periodic signals. I discuss how DATASTUDIO can be used for teaching this detection technique and doing real experiments. Along with a demonstration of lock-in detection, a determination of the Verdet constant with an ac magnetic field is described.
Original language | English |
---|---|
Pages (from-to) | 207-210 |
Number of pages | 4 |
Journal | American Journal of Physics |
Volume | 74 |
Issue number | 3 |
DOIs | |
State | Published - Mar 2006 |