The significance of fluorescence anisotropy in fluorescence intensity and lifetime measurements, and erroneous measurements and interpretations resulting from its disregard, are thoroughly discussed, formulated and quantified. In all fluorescence-related measurements - including excitation and emission spectra, relative fluorescence intensity (FI), fluorescenc life time (FLT), fluorescence resonance energy transfer (FRET), etc., with the exception of fluorescence polarization and anisotropy - it is generally true that the higher the fluorescence anisotropy, the greater the distortion of fluorescence measurements. Quantifiable distortions occur when fluorescence measurements are conducted without considering the influence of fluorescence anisotropy. Here, this influence is described by numerous newly developed mathematical expressions which are simulated and experimentally confirmed utilizing single and binary fluorescent solutions of fluorophores with different spectroscopic characteristics. A marked agreement is shown between the theory and experimental data, clearly indicating the legitimacy of the physical suppositions and the mathematical expressions presented in this paper. Practical and instructive implications are discussed. The following findings are of special applicative importance: 1) the existence of an infinite number of couples of Magic Angles; 2) the deviation between two equally fluorescing particles having different fluorescence anisotropies; 3) the relation between the detected fluorescence intensity and anisotropy when measured under various setups of emission and excitation polarizers; 4) the dependence of the artificial normalized steady-state weight of a single-exponentially decaying fluorophore on its fluorescence anisotropy.

Original languageEnglish
Article number1634508
Pages (from-to)1141-1152
Number of pages12
JournalIEEE Transactions on Biomedical Engineering
Volume53
Issue number6
DOIs
StatePublished - Jun 2006

Bibliographical note

Funding Information:
Manuscript received December 28, 2004; revised November 27, 2005. This work was supported in part by the Horowitz Foundation. Asterisk indicates corresponding author.

Funding

Manuscript received December 28, 2004; revised November 27, 2005. This work was supported in part by the Horowitz Foundation. Asterisk indicates corresponding author.

FundersFunder number
Horowitz Foundation for Social Policy

    Keywords

    • Fluorescence anisotropy
    • Fluorescence intensity
    • Fluorescence lifetime
    • Magic angles

    Fingerprint

    Dive into the research topics of 'Influence of fluorescence anisotropy on fluorescence intensity and lifetime measurement: Theory, simulations and experiments'. Together they form a unique fingerprint.

    Cite this