TY - JOUR
T1 - Improving the adverse changes in cardiac autonomic nervous control during laparoscopic surgery, using an intermittent sequential pneumatic compression device
AU - Bickel, Amitai
AU - Yahalom, Malka
AU - Roguin, Nathan
AU - Ivry, Shimon
AU - Breslava, Jona
AU - Frankel, Roman
AU - Eitan, Arie
PY - 2004/1
Y1 - 2004/1
N2 - Background: The creation of positive pressure pneumoperitoneum (PP) may lead to adverse cardiovascular effects during laparoscopic operations. It can also lead to increased sympathetic cardiac activity, that might have serious consequences. We hypothesized that by reversing the hemodynamic effects, the use of intermittent sequential pneumatic compression device (Lympha-press) on the lower extremities would lead to improved cardiac autonomic control. Methods: This was a prospective cohort study, in which patients served as their own control. Fifteen patients without cardiorespiratory disease undergoing elective laparoscopic cholecystectomy were enrolled prospectively. The activity of the cardiac autonomic nervous system was evaluated by using spectral analysis of heart rate variability, with the Del Mar Avionics 363 (Irvine, California), based on the fast Fourier transformation. The Lympha-press was manipulated several minutes after induction of PP. In each frequency band we measured and compared the power values during anesthesia against those of PP, as well as those of PP against those recorded during activation of Lympha-press. Results: Creation of PP caused increased sympathetic activity, as was manifested by increased power of the low frequency band. Manipulation of the Lympha-Press compression device caused increased parasympathetic activity, as was evident by significant increased power of the high frequency band in all patients. Conclusions: Using an intermittent sequential pneumatic compression device during laparoscopic cholecystectomy may improve cardiac autonomic control by enhancing protective parasympathetic activity. That may have clinical significance, especially in patients suffering from cardiac disease, by improving heart rate variability and elevating the threshold of the occurrence of ventricular arrhythmia.
AB - Background: The creation of positive pressure pneumoperitoneum (PP) may lead to adverse cardiovascular effects during laparoscopic operations. It can also lead to increased sympathetic cardiac activity, that might have serious consequences. We hypothesized that by reversing the hemodynamic effects, the use of intermittent sequential pneumatic compression device (Lympha-press) on the lower extremities would lead to improved cardiac autonomic control. Methods: This was a prospective cohort study, in which patients served as their own control. Fifteen patients without cardiorespiratory disease undergoing elective laparoscopic cholecystectomy were enrolled prospectively. The activity of the cardiac autonomic nervous system was evaluated by using spectral analysis of heart rate variability, with the Del Mar Avionics 363 (Irvine, California), based on the fast Fourier transformation. The Lympha-press was manipulated several minutes after induction of PP. In each frequency band we measured and compared the power values during anesthesia against those of PP, as well as those of PP against those recorded during activation of Lympha-press. Results: Creation of PP caused increased sympathetic activity, as was manifested by increased power of the low frequency band. Manipulation of the Lympha-Press compression device caused increased parasympathetic activity, as was evident by significant increased power of the high frequency band in all patients. Conclusions: Using an intermittent sequential pneumatic compression device during laparoscopic cholecystectomy may improve cardiac autonomic control by enhancing protective parasympathetic activity. That may have clinical significance, especially in patients suffering from cardiac disease, by improving heart rate variability and elevating the threshold of the occurrence of ventricular arrhythmia.
KW - Autonomic nervous system
KW - Cardiac arrhythmia
KW - Laparoscopy
KW - Pneumoperitoneum
UR - http://www.scopus.com/inward/record.url?scp=0346729753&partnerID=8YFLogxK
U2 - 10.1016/j.amjsurg.2003.02.008
DO - 10.1016/j.amjsurg.2003.02.008
M3 - ???researchoutput.researchoutputtypes.contributiontojournal.article???
C2 - 14706602
AN - SCOPUS:0346729753
SN - 0002-9610
VL - 187
SP - 124
EP - 127
JO - American Journal of Surgery
JF - American Journal of Surgery
IS - 1
ER -