TY - JOUR
T1 - Improvement of congestive heart failure by upgrading of conventional to resynchronization pacemakers
AU - Marai, Ibrahim
AU - Gurevitz, Osnat
AU - Carasso, Shemy
AU - Nof, Eyal
AU - Bar-Lev, David
AU - Luria, David
AU - Arbel, Yaron
AU - Freimark, Dov
AU - Feinberg, Micha S.
AU - Eldar, Michael
AU - Glikson, Michael
PY - 2006/8
Y1 - 2006/8
N2 - Aims: To compare the clinical response of patients with right ventricular apical pacing (RVAP) upgraded to cardiac resynchronization therapy (CRT) to that of previously nonpaced heart failure (HF) patients who had de novo CRT implantation. Background: The role of CRT in patients with wide QRS and HF due to RVAP is less well established than in other CRT candidates. Methods: Ninety-eight consecutive patients with CRT were studied (mean age 70, mean ejection fraction 0.23). Group A: patients having RVAP prior to CRT implantation (n = 25), group B: patients without prior RVAP (n = 73). Clinical and echocardiographic parameters were recorded prior to, and 3 months after, CRT implantation. Results: Group A patients had a wider QRS at baseline compared to group B (203 ± 32 ms vs 163 ± 30 ms respectively, P < 0.001), and a shorter 6-minute walking distance (222 ± 118 m vs 362 ± 119 m, respectively, P < 0.005). Otherwise, clinical and echocardiographic parameters were not different. At follow up, group A patients had an average 0.7 ± 0.5 decrease in their NYHA functional class, compared to 0.3 ± 0.7 in group B patients (P < 0.05). Six-minute walking distance increased by 93 ± 113 m in group A, versus 36 ± 120 m in group B (P = 0.22). There was no difference in echocardiographic response to CRT between the groups. Conclusions: HF patients with prior RVAP demonstrate clinical improvement after upgrading to CRT that is comparable, and in some aspects, even better than that observed in HF patients with native conduction delay who undergo de novo CRT implantation.
AB - Aims: To compare the clinical response of patients with right ventricular apical pacing (RVAP) upgraded to cardiac resynchronization therapy (CRT) to that of previously nonpaced heart failure (HF) patients who had de novo CRT implantation. Background: The role of CRT in patients with wide QRS and HF due to RVAP is less well established than in other CRT candidates. Methods: Ninety-eight consecutive patients with CRT were studied (mean age 70, mean ejection fraction 0.23). Group A: patients having RVAP prior to CRT implantation (n = 25), group B: patients without prior RVAP (n = 73). Clinical and echocardiographic parameters were recorded prior to, and 3 months after, CRT implantation. Results: Group A patients had a wider QRS at baseline compared to group B (203 ± 32 ms vs 163 ± 30 ms respectively, P < 0.001), and a shorter 6-minute walking distance (222 ± 118 m vs 362 ± 119 m, respectively, P < 0.005). Otherwise, clinical and echocardiographic parameters were not different. At follow up, group A patients had an average 0.7 ± 0.5 decrease in their NYHA functional class, compared to 0.3 ± 0.7 in group B patients (P < 0.05). Six-minute walking distance increased by 93 ± 113 m in group A, versus 36 ± 120 m in group B (P = 0.22). There was no difference in echocardiographic response to CRT between the groups. Conclusions: HF patients with prior RVAP demonstrate clinical improvement after upgrading to CRT that is comparable, and in some aspects, even better than that observed in HF patients with native conduction delay who undergo de novo CRT implantation.
KW - Cardiac resynchronization
KW - Heart failure
KW - Right ventricular apical pacemaker upgrading
UR - http://www.scopus.com/inward/record.url?scp=33747117580&partnerID=8YFLogxK
U2 - 10.1111/j.1540-8159.2006.00455.x
DO - 10.1111/j.1540-8159.2006.00455.x
M3 - ???researchoutput.researchoutputtypes.contributiontojournal.article???
C2 - 16923005
AN - SCOPUS:33747117580
SN - 0147-8389
VL - 29
SP - 880
EP - 884
JO - PACE - Pacing and Clinical Electrophysiology
JF - PACE - Pacing and Clinical Electrophysiology
IS - 8
ER -