Skip to main navigation Skip to search Skip to main content

Impact of Ultrasound Transducer Positioning on Acoustic Particle Manipulation in the Anterior Chamber

  • Jacob Nagler
  • , Avraham Kenigsberg
  • , Ornit Nagler-Avramovitz
  • , Heli Peleg-Levy
  • , Shelly Zlotnikov
  • , Silvia Piperno
  • , Noa Kapelushnik
  • , Shany Shperling
  • , Alon Skaat
  • , Ari Leshno
  • , Hagay Shpaisman
  • NIRC
  • Bar-Ilan University
  • Tel Aviv University
  • Sheba Medical Center at Tel Hashomer

Research output: Contribution to journalArticlepeer-review

Abstract

Purpose: A novel noninvasive technique utilizing standing acoustic waves has been developed to trap and redirect intraocular particles within the anterior chamber, presenting a potential preventive treatment for pathologies such as hyphema and pigmentary glaucoma. Because clinical translation requires a rigorous understanding of the influence of geometric parameters, the purpose of this study is to investigate the effects of transducer positioning, incidence angle, and impact contour to define the operational window for successful acoustic manipulation. Methods: We conducted experimental and numerical investigations to evaluate how acoustic trapping at nodal regions can be used to guide particles away from the trabecular meshwork. To thoroughly assess the particle manipulation, the experimental results were quantitatively analyzed and validated against a two-dimensional Finite Element Acoustic Model (FEAM) alongside theoretical Gor’kov radiation force calculations to predict nodal formation and trap stability. Results: Our findings indicate that low incidence angles (5°–15°) are critical for maximizing the effective standing wave potential and ensuring efficient particle control. Conversely, incidence angles exceeding 30° result in a transition from stable standing waves to acoustic streaming dominance, which serves as the primary failure mode. Furthermore, while a 4 mm impact contour at 15° improves trapping consistency along the x-axis compared to a 2 mm contour, broader z-axis streaks imply trade-offs regarding effective particle sweeping. The FEAM and Gor’kov force calculations demonstrated high compatibility in predicting the experimental nodal formations. Conclusions: This study quantitatively establishes the geometric baselines and operational windows required to optimize intraocular acoustic manipulation. By identifying the optimal transducer parameters and acoustic streaming failure modes, these findings provide a crucial foundation for the future clinical translation of this noninvasive technique.

Original languageEnglish
Article number189
JournalJournal of Vibration Engineering and Technologies
Volume14
Issue number4
DOIs
StatePublished - Apr 2026

Bibliographical note

Publisher Copyright:
© Springer Nature Singapore Pte Ltd. 2026.

Keywords

  • Acoustic manipulation
  • Acoustic radiation force (ARF)
  • Acoustic streaming
  • Anterior chamber
  • Biomedical ultrasound
  • Finite element analysis (FEAM)
  • Glaucoma prevention
  • Intraocular particles
  • Standing waves

Fingerprint

Dive into the research topics of 'Impact of Ultrasound Transducer Positioning on Acoustic Particle Manipulation in the Anterior Chamber'. Together they form a unique fingerprint.

Cite this