Abstract
Electric measurements carried out on the silk caps formed by hornet larvae prior to their pupation have shown that under optimal conditions (30°C and 90% relative humidity) there were significant, albeit reversible, differences between the silk response to visible light vs. darkness. Thus, following electrical charging under illumination, we obtained current value of a few nA only, a voltage ranging from dozens to hundreds of mV and a resistance ranging from hundreds of kΩ to several GΩ, Contrarywise, in darkness, the equivalent values were dozens to hundreds of nA, a voltage of dozens of mV and a resistance ranging from several dozens to several hundred kQ. Insofar as these values were concerned, the transition was almost immediate upon a change in the illumination intensity of about 15,000 Lux/cm2. On the basis of these measurable values, the amount of electric charge could be computed in Coulombs, whereupon the efficiency was found to be greater by 1 × 103 -1 × 105 in the dark than in light. The biological rationale underlying these properties and the sharp transition in response to light and darkness are discussed.
| Original language | English |
|---|---|
| Pages (from-to) | 95-108 |
| Number of pages | 14 |
| Journal | Physiological Chemistry and Physics and Medical NMR |
| Volume | 29 |
| Issue number | 1 |
| State | Published - 1 Dec 1997 |
Fingerprint
Dive into the research topics of 'I. On Hornet Silk as a Photodetector: Considerations of Current, Voltage and Resistance: Considerations of Current, Voltage and Resistance'. Together they form a unique fingerprint.Cite this
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver