TY - JOUR
T1 - Hemodynamic and mechanical aspects of fenestrated endografts for treatment of Abdominal Aortic Aneurysm
AU - Avrahami, Idit
AU - Brand, Moshe
AU - Meirson, Tomer
AU - Ovadia-Blechman, Zehava
AU - Halak, Moshe
PY - 2012/9
Y1 - 2012/9
N2 - Fenestrated endovascular aneurysm repair (f-EVAR) stent grafts offer an alternative treatment for conventional open heart surgery for patients with juxsta-renal Abdominal Aortic Aneurysms (AAA) that are unsuitable for the common infrarenal endovascular aneurysms repair (EVAR) procedure. The f-EVAR endograft includes branched stent grafts fixed to the aortic endograft main body via designated strengthened fenestrations. Repetitive stresses activated upon the endograft by the pulsatile flow might cause detachment or fracture of branching. Thus, investigation of the flow forces and stresses on the graft may help minimize complications and improve the endograft design. The present work investigates the flow and stress fields of the fenestrated endograft configuration using a fluid structure interaction (FSI) model in order to evaluate risks for graft fracture or detachments. The results show that the f-EVAR dramatically improves the aortic and iliac flow and that elevated cyclic stresses are found at the graft's bifurcation and branches' connections.
AB - Fenestrated endovascular aneurysm repair (f-EVAR) stent grafts offer an alternative treatment for conventional open heart surgery for patients with juxsta-renal Abdominal Aortic Aneurysms (AAA) that are unsuitable for the common infrarenal endovascular aneurysms repair (EVAR) procedure. The f-EVAR endograft includes branched stent grafts fixed to the aortic endograft main body via designated strengthened fenestrations. Repetitive stresses activated upon the endograft by the pulsatile flow might cause detachment or fracture of branching. Thus, investigation of the flow forces and stresses on the graft may help minimize complications and improve the endograft design. The present work investigates the flow and stress fields of the fenestrated endograft configuration using a fluid structure interaction (FSI) model in order to evaluate risks for graft fracture or detachments. The results show that the f-EVAR dramatically improves the aortic and iliac flow and that elevated cyclic stresses are found at the graft's bifurcation and branches' connections.
KW - AAA
KW - FSI
KW - Fenestrated endovascular repair
UR - http://www.scopus.com/inward/record.url?scp=84861827850&partnerID=8YFLogxK
U2 - 10.1016/j.euromechflu.2012.03.010
DO - 10.1016/j.euromechflu.2012.03.010
M3 - ???researchoutput.researchoutputtypes.contributiontojournal.article???
AN - SCOPUS:84861827850
SN - 0997-7546
VL - 35
SP - 85
EP - 91
JO - European Journal of Mechanics, B/Fluids
JF - European Journal of Mechanics, B/Fluids
ER -