Abstract
We demonstrate a method for single-detector coherent sensing and automated coalignment of group delays in a coherently combined laser array, enabling robust coherent combining of broadband sources despite initial path mismatches exceeding the laser coherence length. The method is based on Fourier-domain filtering of the coherently combined laser beam to extract error signals, and it is equally applicable to controlling both spatial and temporal misalignments.
Original language | English |
---|---|
Pages (from-to) | 455-457 |
Number of pages | 3 |
Journal | Optics Letters |
Volume | 37 |
Issue number | 4 |
DOIs | |
State | Published - 15 Feb 2012 |
Externally published | Yes |