TY - JOUR
T1 - Graft and mesh use in transvaginal prolapse repair
AU - Schimpf, Megan O.
AU - Abed, Husam
AU - Sanses, Tatiana
AU - White, Amanda B.
AU - Lowenstein, Lior
AU - Ward, Renée M.
AU - Sung, Vivian W.
AU - Balk, Ethan M.
AU - Murphy, Miles
N1 - Publisher Copyright:
© 2016 by The American College of Obstetricians and Gynecologists. Published by Wolters Kluwer Health, Inc.
PY - 2016/7/1
Y1 - 2016/7/1
N2 - OBJECTIVE: To update clinical practice guidelines on graft and mesh use in transvaginal pelvic organ prolapse repair based on systematic review. DATA SOURCES: Eligible studies, published through April 2015, were retrieved through ClinicalTrials.gov, MEDLINE, and Cochrane databases and bibliography searches. METHODS OF STUDY SELECTION: We included studies of transvaginal prolapse repair that compared graft or mesh use with either native tissue repair or use of a different graft or mesh with anatomic and symptomatic outcomes with a minimum of 12 months of follow-up. TABULATION, INTEGRATION, AND RESULTS: Study data were extracted by one reviewer and confirmed by a second reviewer. Studies were classified by vaginal compartment (anterior, posterior, apical, or multiple), graft type (biologic, synthetic absorbable, synthetic nonabsorbable), and outcome (anatomic, symptomatic, sexual function, mesh complications, and return to the operating room). We found 66 comparative studies reported in 70 articles, including 38 randomized trials; quality of the literature has improved over time, but some outcomes still show heterogeneity and limited power. In the anterior vaginal compartment, synthetic nonabsorbable mesh consistently showed improved anatomic and bulge symptom outcomes compared with native tissue repairs based on meta-analyses. Other subjective outcomes, including urinary incontinence or dyspareunia, generally did not differ. Biologic graft or synthetic absorbable mesh use did not provide an advantage in any compartment. Synthetic mesh use in the posterior or apical compartments did not improve success. Mesh erosion rates ranged from 1.4-19% at the anterior vaginal wall, but 3-36% when mesh was placed in multiple compartments. Operative mesh revision rates ranged from 3-8%. CONCLUSION: Synthetic mesh augmentation of anterior wall prolapse repair improves anatomic outcomes and bulge symptoms compared with native tissue repair. Biologic grafts do not improve prolapse repair outcomes in any compartment. Mesh erosion occurred in up to 36% of patients, but reoperation rates were low.
AB - OBJECTIVE: To update clinical practice guidelines on graft and mesh use in transvaginal pelvic organ prolapse repair based on systematic review. DATA SOURCES: Eligible studies, published through April 2015, were retrieved through ClinicalTrials.gov, MEDLINE, and Cochrane databases and bibliography searches. METHODS OF STUDY SELECTION: We included studies of transvaginal prolapse repair that compared graft or mesh use with either native tissue repair or use of a different graft or mesh with anatomic and symptomatic outcomes with a minimum of 12 months of follow-up. TABULATION, INTEGRATION, AND RESULTS: Study data were extracted by one reviewer and confirmed by a second reviewer. Studies were classified by vaginal compartment (anterior, posterior, apical, or multiple), graft type (biologic, synthetic absorbable, synthetic nonabsorbable), and outcome (anatomic, symptomatic, sexual function, mesh complications, and return to the operating room). We found 66 comparative studies reported in 70 articles, including 38 randomized trials; quality of the literature has improved over time, but some outcomes still show heterogeneity and limited power. In the anterior vaginal compartment, synthetic nonabsorbable mesh consistently showed improved anatomic and bulge symptom outcomes compared with native tissue repairs based on meta-analyses. Other subjective outcomes, including urinary incontinence or dyspareunia, generally did not differ. Biologic graft or synthetic absorbable mesh use did not provide an advantage in any compartment. Synthetic mesh use in the posterior or apical compartments did not improve success. Mesh erosion rates ranged from 1.4-19% at the anterior vaginal wall, but 3-36% when mesh was placed in multiple compartments. Operative mesh revision rates ranged from 3-8%. CONCLUSION: Synthetic mesh augmentation of anterior wall prolapse repair improves anatomic outcomes and bulge symptoms compared with native tissue repair. Biologic grafts do not improve prolapse repair outcomes in any compartment. Mesh erosion occurred in up to 36% of patients, but reoperation rates were low.
UR - http://www.scopus.com/inward/record.url?scp=84973358410&partnerID=8YFLogxK
U2 - 10.1097/aog.0000000000001451
DO - 10.1097/aog.0000000000001451
M3 - ???researchoutput.researchoutputtypes.contributiontojournal.systematicreview???
C2 - 27275813
AN - SCOPUS:84973358410
SN - 0029-7844
VL - 128
SP - 81
EP - 91
JO - Obstetrics and Gynecology
JF - Obstetrics and Gynecology
IS - 1
ER -