Full field of view super-resolution imaging based on two static gratings and white light illumination

Javier García, Vicente Micó, Dan Cojoc, Zeev Zalevsky

Research output: Contribution to journalArticlepeer-review

16 Scopus citations

Abstract

The usage of two static gratings for obtaining super-resolved imaging dates back to the work by Bachl and Lukosz in 1967. However, in their approach a severe reduction in the field of view was the necessary condition for improving the resolution. We present an approach based on two static gratings without sacrificing the field of view. The key idea for not paying with the field of view is to use white light illumination to average the ghost images obtained outside the region of interest since the positions of those images are wavelength dependent. Moreover, large magnification is achieved by using a commercial microscope objective instead of a test system with a unity magnification as presented in previous works. Because of the large magnification, the second grating has a low spatial period. This allows us to create an intermediate image and use a second imaging lens with low resolution capability while still obtaining an imaging quality as good as that provided by the first imaging lens. This is an important improvement in comparison with the original super-resolving method with two fixed gratings.

Original languageEnglish
Pages (from-to)3080-3087
Number of pages8
JournalApplied Optics
Volume47
Issue number17
DOIs
StatePublished - 10 Jun 2008

Fingerprint

Dive into the research topics of 'Full field of view super-resolution imaging based on two static gratings and white light illumination'. Together they form a unique fingerprint.

Cite this