Abstract

Objective: If a gold standard is lacking in a diagnostic test accuracy study, expert diagnosis is frequently used as reference standard. However, interobserver and intraobserver agreements are imperfect. The aim of this study was to quantify the reproducibility of a panel diagnosis for pediatric infectious diseases. Study Design and Setting: Pediatricians from six countries adjudicated a diagnosis (i.e., bacterial infection, viral infection, or indeterminate)for febrile children. Diagnosis was reached when the majority of panel members came to the same diagnosis, leaving others inconclusive. We evaluated intraobserver and intrapanel agreement with 6 weeks and 3 years’ time intervals. We calculated the proportion of inconclusive diagnosis for a three-, five-, and seven-expert panel. Results: For both time intervals (i.e., 6 weeks and 3 years), intrapanel agreement was higher (kappa 0.88, 95%CI: 0.81-0.94 and 0.80, 95%CI: NA)compared to intraobserver agreement (kappa 0.77, 95%CI: 0.71-0.83 and 0.65, 95%CI: 0.52-0.78). After expanding the three-expert panel to five or seven experts, the proportion of inconclusive diagnoses (11%)remained the same. Conclusion: A panel consisting of three experts provides more reproducible diagnoses than an individual expert in children with lower respiratory tract infection or fever without source. Increasing the size of a panel beyond three experts has no major advantage for diagnosis reproducibility.

Original languageEnglish
Pages (from-to)20-27
Number of pages8
JournalJournal of Clinical Epidemiology
Volume112
DOIs
StatePublished - Aug 2019

Bibliographical note

Publisher Copyright:
© 2019 Elsevier Inc.

Funding

FundersFunder number
Seventh Framework Programme602860

    UN SDGs

    This output contributes to the following UN Sustainable Development Goals (SDGs)

    1. SDG 3 - Good Health and Well-being
      SDG 3 Good Health and Well-being

    Keywords

    • Diagnosis
    • Expert panel
    • Gold standard
    • Infectious diseases
    • Reference standard
    • Reproducibility

    Fingerprint

    Dive into the research topics of 'Expert panel diagnosis demonstrated high reproducibility as reference standard in infectious diseases'. Together they form a unique fingerprint.

    Cite this