Enantiomerization study of atropine and its semipreparative enantioseparation along with (1 RS,2 SR)-(±)-ephedrine on polyacrylamide column using high-performance liquid chromatography

Rajender Kumar, Jürgen Martens, Ravi Bhushan

Research output: Contribution to journalArticlepeer-review

6 Scopus citations

Abstract

Enantiomerization of atropine was studied at ambient temperature using analytical chiral polyacrylamide column under reversed phase conditions without the use of external stimulants such as heat or catalysts; mobile phase consisting of polar organic solvents (methanol-0.2% acetic acid in water, 60:40, v/v) with detection at 230 nm was successful for resolving enantiomers of atropine and (1RS,2SR)-(±)-ephedrine. Addition of small amount of acetic acid in mobile phase was found to be essential for enantioseparation. The same mobile phase composition was found successful to investigate enatiomerization of atropine during routine runs on chromatographic time scale. The enantiomerization rate of (S)-(-)-hyoscyamine and (R)-(+)-hyoscyamine was found to be different but insignificant to result in the formation of non-racemic mixture. The analytical method developed was easily augmented to the semipreparative separation and recovery of enantiomers of drug in mg scale. The sample obtained was found to be free of enatiomerization product. The analytical method was successful for the determination of enantiomeric composition in pharmaceutical dosage form.

Original languageEnglish
Pages (from-to)111-116
Number of pages6
JournalJournal of Liquid Chromatography and Related Technologies
Volume38
Issue number1
DOIs
StatePublished - 2 Jan 2015
Externally publishedYes

Bibliographical note

Publisher Copyright:
© Taylor & Francis Group, LLC.

Funding

Award of a senior research fellowship to R. Kumar by the Council of Scientific and Industrial Research, New Delhi, India, and the scientific donation of Knauer HPLC equipment to R. Bhushan by the Alexander von Humboldt-Stiftung, Bonn, Germany, are gratefully acknowledged. Thanks are due to Indian Institute of Technology Roorkee (for granting leave of absence to R. Bhushan and to the Alexander von Humboldt-Stiftung, Bonn, Germany for the award of a fellowship to R. Bhushan in 2013.

FundersFunder number
Alexander von Humboldt-Stiftung
Council of Scientific and Industrial Research, India
Indian Institute of Technology Roorkee

    Keywords

    • atropine
    • direct enantioseparation
    • enantiomerization
    • ephedrine
    • polyacrylamide column
    • preparative separation

    Fingerprint

    Dive into the research topics of 'Enantiomerization study of atropine and its semipreparative enantioseparation along with (1 RS,2 SR)-(±)-ephedrine on polyacrylamide column using high-performance liquid chromatography'. Together they form a unique fingerprint.

    Cite this