Double-balloon instillation device for second-trimester abortion: Outcome in 340 consecutive cases

H. Abramovici, J. Bornstein, Y. Ben-David, D. Yishai, A. Rofe, J. Atad

Research output: Contribution to journalArticlepeer-review

8 Scopus citations

Abstract

For the past five years we have used a double-balloon device for extraovular installation of prostaglandin solution for termination of midtrimester pregnancy. In 340 consecutive cases a success rate of 91% (abortions within 24 hours) was achieved, with a mean instillation-to- abortion interval of 17.5 ± 6.5 (SD) hours in nulliparas versus 12.8 ± 6.1 in multiparas (P < .005). The instillation of continuous, low-dose prostaglandin solution into the extraovular space resulted in very few side effects and no complications. Furthermore, the technique was used successfully in women who had undergone one or more cesarean sections in the past. The use of prostaglandin E 2 (PGE 2) resulted in shorter installation- to-abortion intervals than did prostaglandin F(2α) (P < .01); 500 μg/h of PGE 2 solution was needed in nulliparas, whereas 250 sufficed in multiparas.

Original languageEnglish
Pages (from-to)56-62
Number of pages7
JournalJournal of Reproductive Medicine
Volume40
Issue number1
StatePublished - Jan 1995
Externally publishedYes

Fingerprint

Dive into the research topics of 'Double-balloon instillation device for second-trimester abortion: Outcome in 340 consecutive cases'. Together they form a unique fingerprint.