Abstract
Chemotherapy is a widely used effective method for the treatment of cancer in humans. Severity of dose levels and treatment duration necessitate frequent continuous monitoring of active drug concentration in human serum and urine. Development of an electrochemical biosensor for direct determination of methotrexate (MTX), a chemotherapy agent, from physiological fluids has been investigated. Functionalized multi-walled carbon nanotube paste electrodes (f-CNTPE) have been fabricated for simple, cost-effective and reusable electrochemical sensors. Scanning electron microscopy studies revealed that the fabricated electrode surface is comprised of nano-streaks of independent segregated CNTs with high porosity. Cyclic voltammetric analysis showed that f-CNTPE had an enhanced electrocatalytic activity with sensitivity as much as three times and less over potentials by 70 mV compared with a conventional carbon paste electrode. Under optimized experimental parameters, differential pulse voltammograms (DPVs) exhibited a gradual increase in peak current with concentration, and the plot of peak current against MTX concentration was linear in the range of 0.4–5.5 μM. Square-wave voltammetry analysis of methotrexate exhibited a linear determination range from 0.01 to 1.5 μM, and the low-detection-limit was 2.9 × 10 −9 M. Steady-state current–time analysis mimic to hydrodynamic flow-cell experiments demonstrated a low-detection-limit of 10 nM (S/N ratio ~8) and an analysis time of mere 10 s. Selective determination of MTX at micromolar concentrations in the presence of a mixture of possible electroactive interferents, ascorbic acid, dopamine, etc. (1.5 μM each) is successfully demonstrated. The electrochemical biosensor allows the detection of MTX in-vitro directly from pharmaceutical drug, human serum and undiluted urine samples at very low concentration limits of as low as 5.0 × 10 −7 M with recovery error limits of 4.5% at maximum.
| Original language | English |
|---|---|
| Pages (from-to) | 626-633 |
| Number of pages | 8 |
| Journal | Microchemical Journal |
| Volume | 148 |
| DOIs | |
| State | Published - Jul 2019 |
| Externally published | Yes |
Bibliographical note
Publisher Copyright:© 2019
Funding
The authors gratefully acknowledge National Institute of Technology Warangal and Ministry of Human Resource Development, India for Doctoral Research Fellowship to Shekher Kummari and financial support.
| Funders |
|---|
| National Institute of Technology Warangal |
| Ministry of Human Resource Development |
UN SDGs
This output contributes to the following UN Sustainable Development Goals (SDGs)
-
SDG 3 Good Health and Well-being
Keywords
- Chemotherapy
- Methotrexate
- Serum analysis
- Square wave voltammetry
- Urine analysis