TY - JOUR
T1 - Comparison of two different speckle tracking software systems
T2 - Does the method matter?
AU - Biaggi, Patric
AU - Carasso, Shemy
AU - Garceau, Patrick
AU - Greutmann, Matthias
AU - Gruner, Christiane
AU - Tsang, Wendy
AU - Rakowski, Harry
AU - Agmon, Yoram
AU - Woo, Anna
PY - 2011/5
Y1 - 2011/5
N2 - Background: Echocardiographic speckle tracking strain has gained clinical importance. However, the comparability of measurements between different software systems is not well defined. Methods: In 47 healthy subjects left ventricular (LV) two-dimensional (2D) peak strain and time to peak strain (TTP) generated by EchoPAC (2DS) and velocity vector imaging (VVI) were compared. For each type of strain (longitudinal [LS], circumferential [CS], and radial strain [RS]) we compared global, anatomical level and segmental values. Results: When comparing 2DS to VVI, Pearson correlation coefficients (r) of global LS, CS, and RS were 0.68, 0.44, and 0.59, respectively (all P < 0.05). Correlation of global TTP was higher: 0.81(LS), 0.80 (CS), and 0.68 (RS), all P < 0.01. Segmental peak strain differed significantly between 2DS and VVI in 8/18 (LS), 17/18 (CS), and 15/18 (RS) LV segments (P < 0.05). However, segmental TTP significantly differed only in 5/18 (LS), 7/18 (CS), and 4/18 (RS) of LV segments. Similar strain gradients were found for both systems: apical strain was higher than basal and midventricular strain in LS and CS, with a reversed pattern for RS (P < 0.05). Conclusion: TTP strain as well as strain gradients were comparable between VVI and 2DS, but most peak strain values were not. The software-dependency of peak strain values must be considered in clinical application. Further studies comparing the diagnostic and prognostic accuracy of strain values generated by different software systems are mandatory.
AB - Background: Echocardiographic speckle tracking strain has gained clinical importance. However, the comparability of measurements between different software systems is not well defined. Methods: In 47 healthy subjects left ventricular (LV) two-dimensional (2D) peak strain and time to peak strain (TTP) generated by EchoPAC (2DS) and velocity vector imaging (VVI) were compared. For each type of strain (longitudinal [LS], circumferential [CS], and radial strain [RS]) we compared global, anatomical level and segmental values. Results: When comparing 2DS to VVI, Pearson correlation coefficients (r) of global LS, CS, and RS were 0.68, 0.44, and 0.59, respectively (all P < 0.05). Correlation of global TTP was higher: 0.81(LS), 0.80 (CS), and 0.68 (RS), all P < 0.01. Segmental peak strain differed significantly between 2DS and VVI in 8/18 (LS), 17/18 (CS), and 15/18 (RS) LV segments (P < 0.05). However, segmental TTP significantly differed only in 5/18 (LS), 7/18 (CS), and 4/18 (RS) of LV segments. Similar strain gradients were found for both systems: apical strain was higher than basal and midventricular strain in LS and CS, with a reversed pattern for RS (P < 0.05). Conclusion: TTP strain as well as strain gradients were comparable between VVI and 2DS, but most peak strain values were not. The software-dependency of peak strain values must be considered in clinical application. Further studies comparing the diagnostic and prognostic accuracy of strain values generated by different software systems are mandatory.
KW - echocardiography
KW - left ventricular function
KW - myocardial strain
UR - http://www.scopus.com/inward/record.url?scp=79956156965&partnerID=8YFLogxK
U2 - 10.1111/j.1540-8175.2011.01386.x
DO - 10.1111/j.1540-8175.2011.01386.x
M3 - ???researchoutput.researchoutputtypes.contributiontojournal.article???
C2 - 21517954
AN - SCOPUS:79956156965
SN - 0742-2822
VL - 28
SP - 539
EP - 547
JO - Echocardiography
JF - Echocardiography
IS - 5
ER -