TY - JOUR
T1 - Biocompatibility of a polymeric implant for the treatment of osteomyelitis
AU - Brin, Y. S.
AU - Nyska, A.
AU - Domb, A. J.
AU - Golenser, J.
AU - Mizrahi, B.
AU - Nyska, M.
PY - 2009/4/1
Y1 - 2009/4/1
N2 - We evaluated the biocompatibility of an injectable gelling polymeric device for the controlled release of gentamicin sulfate in the treatment of invasive bacterial infections in bone of male Wister rats. The biodegradable delivery carrier, poly(sebacic-co-ricinoleic-ester-anhydride), designated as p(SA:RA), was injected, with and without gentamicin, into the tibial canal. Rats were killed 3 weeks later. The tibiae were processed histologically, leaving the injectable polymer in situ. The local tissue reaction to the polymer with or without antibiotic consisted mainly of mild reactive fibroplasia/fibrosis and mild to moderate increased reactive bone formation. At this stage, no evidence for any active inflammatory response to the polymer was seen. Thus, the injection of p(SA:RA) was well tolerated and did not induce any signs of a progressive inflammatory reaction.
AB - We evaluated the biocompatibility of an injectable gelling polymeric device for the controlled release of gentamicin sulfate in the treatment of invasive bacterial infections in bone of male Wister rats. The biodegradable delivery carrier, poly(sebacic-co-ricinoleic-ester-anhydride), designated as p(SA:RA), was injected, with and without gentamicin, into the tibial canal. Rats were killed 3 weeks later. The tibiae were processed histologically, leaving the injectable polymer in situ. The local tissue reaction to the polymer with or without antibiotic consisted mainly of mild reactive fibroplasia/fibrosis and mild to moderate increased reactive bone formation. At this stage, no evidence for any active inflammatory response to the polymer was seen. Thus, the injection of p(SA:RA) was well tolerated and did not induce any signs of a progressive inflammatory reaction.
KW - Biocompatible degradable polymer
KW - Controlled delivery
KW - Gentamicin
KW - Tibial implant
KW - Toxicity evaluation
UR - http://www.scopus.com/inward/record.url?scp=67649099938&partnerID=8YFLogxK
U2 - 10.1163/156856209x444439
DO - 10.1163/156856209x444439
M3 - ???researchoutput.researchoutputtypes.contributiontojournal.article???
C2 - 19454170
AN - SCOPUS:67649099938
SN - 0920-5063
VL - 20
SP - 1081
EP - 1090
JO - Journal of Biomaterials Science, Polymer Edition
JF - Journal of Biomaterials Science, Polymer Edition
IS - 7-8
ER -